The corporation upholds the philosophy of "Be No.1 in excellent, be rooted on credit rating and trustworthiness for growth", will proceed to provide aged and new buyers from home and abroad whole-heatedly for Uv Lamp, Impact Hammer Test Concrete, Best Surface Roughness Tester, We would like to take this opportunity to establish long-term business relationships with clients from all over the world.
Wholesale Film Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:

ery (2)

● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored

Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

Technical Specifications:

<td ” width=”284″>Measuring range  <td ” width=”284″>0-1250µ with standard probe F1.N1 (10.000mm    max)<td ” width=”284″>Probes available  <td ” width=”284″>5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)<td ” width=”284″>Tolerance  <td ” width=”284″>F1:±(1µ+3%H) N1.±(1.5µ+3% H)H: actual thickness tested<td ” width=”284″>Resolution <td ” width=”284″>Alphanumeric with 4 large digits<td ” width=”284″>Operation language <td ” width=”284″>English<td ” width=”284″>Standards <td ” width=”284″>DIN, ISO, ASTM,BS<td ” width=”284″>Min. measuring area <td ” width=”284″>F1:(standard probe)<td ” width=”284″>Min. curvature  radius <td ” width=”284″>convex:3mm, concave:50mm<td ” width=”284″>Min. substratethickness <td ” width=”284″>type F: 0.5mm, type N: 50mm<td ” width=”284″>Calibration <td ” width=”284″>Zero and foil calibration<td ” width=”284″>Statistics  <td ” width=”284″>Number of measurements, mean, standard deviation,maximum and minimum of 3000readings<td ” width=”284″>Data memory <td ” width=”284″>500  measuring data<td ” width=”284″>Limits <td ” width=”284″>Adjustable with acoustic alarm<td ” width=”284″>Interface <td ” width=”284″>USB 2.0<td ” width=”284″>Operating temperature <td ” width=”284″>0-40℃<td ” width=”284″>power supply <td ” width=”284″>AA size 1.5V<td ” width=”284″>Dimensions <td ” width=”284″>125*67*31mm (main unit)<td ” width=”284″>Weight <td ” width=”284″>345.g

Standard Delivery

·  Main unit 1
·  Probe F1 or N1 1
·  Calibration foils 5
·  Instruction manual 1
·   Cetificate 1
·  Warranty card 1
·  Carrying case 1
Communication cable 1
PC software Dataview 1

Optional accessories
●5 probes for different applications
●Calibration foils in various thickness

ery (1)

Type F probe:

<td ” width=”47″>F5<td ” width=”122″> <td ” width=”47″>1.5<td ” width=”47″>

F7

F7

F40

<td ” width=”47″>

0.5

0.5

2

Probe

F400

F1

F1/90°

F10

Measuring Principle Magnetic method
Measuring range(mm)

0400um

01250 um

010000

Min resolution(mm)

0.1

0.1

10

Tolerance One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm) ±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

flat

10

 Minimum measuring area(mm)

F3

Minimum thickness of base material(mm)

0.2

Type N probe

Probe N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0400

01250

10200

 Min resolution(mm)

0.1

0.1

1

Tolerance  One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm) ±(1%H+0.7) ±1%H+1.5

——–

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0


Product detail pictures:

Wholesale Film Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures


Related Product Guide:

Every single member from our higher effectiveness product sales staff values customers' requires and organization communication for Wholesale Film Coating Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: Mexico, Nicaragua, Russia, Our monthly output is more than 5000pcs. We have set up a strict quality control system. Please feel free to contact us for further information. We hope that we can establish long-term business relationships with you and carry out business on a mutually beneficial basis. We are and will be always trying our best to serve you.
  • This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Myrna from Chile - 2017.05.02 11:33
    Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
    5 Stars By Poppy from Auckland - 2017.09.26 12:12
    Write your message here and send it to us