Have a question? Give us a call: +8613911515082

Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We also present product or service sourcing and flight consolidation products and services. We have our possess manufacturing facility and sourcing place of work. We can easily supply you with almost every type of product or service connected to our item variety for Rebound Hammer Test Standard, Ec Conductivity Meter, Pencil Hardness Test For Paint, Our clients mainly distributed in the North America, Africa and Eastern Europe. we can supply high quality products with the very competitive price.
Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:

● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored

IMG_5037

Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

NDT certificate

Technical Specifications:

Measuring range 0-1250µ with standard probe F1.N1 (10.000mm    max)
Probes available 5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
Tolerance F1:±(1µ+3%H) N1.±(1.5µ+3% H)H: actual thickness tested
Resolution Alphanumeric with 4 large digits
Operation language English
Standards DIN, ISO, ASTM,BS
Min. measuring area F1:(standard probe)
Min. curvature  radius convex:3mm, concave:50mm
Min. substratethickness type F: 0.5mm, type N: 50mm
Calibration Zero and foil calibration
Statistics Number of measurements, mean, standard deviation,maximum and minimum of 3000readings
Data memory 500  measuring data
Limits Adjustable with acoustic alarm
Interface USB 2.0
Operating temperature 0-40℃
power supply AA size 1.5V
Dimensions 125*67*31mm (main unit)
Weight 345.g

Standard Delivery

·  Main unit 1
·  Probe F1 or N1 1
·  Calibration foils 5
·  Instruction manual 1
·   Cetificate 1
·  Warranty card 1
·  Carrying case 1
Communication cable 1
PC software Dataview 1

Optional accessories
●5 probes for different applications
●Calibration foils in various thickness

Coating-thickness-tester2

Type F probe:

Probe

F400

F1

F1/90°

F10

Measuring Principle

Magnetic method

Measuring range(mm)

0~400um

0~1250 um

0~10000

Min resolution(mm)

0.1

0.1

10

Tolerance

One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm)

±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

flat

10

 Minimum measuring area(mm)

F3

F7

F7

F40

Minimum thickness of base material(mm)

0.2

0.5

0.5

2

Type N probe

Probe N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0~400

0~1250

10~200

 Min resolution(mm)

0.1

0.1

1

Tolerance  One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm) ±(1%H+0.7) ±(1%H+1.5)

——–

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0

factory


Product detail pictures:

Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures

Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures

Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures

Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck detail pictures


Related Product Guide:

To fulfill the customers' over-expected fulfillment , we have now our solid staff to deliver our greatest general assistance which includes internet marketing, product sales, creating, manufacturing, excellent controlling, packing, warehousing and logistics for Manufactur standard Wall Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: Colombia, Thailand, Panama, We'll initiate the second phase of our development strategy. Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. If you are interested in any of our products and solutions or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Ivy from Eindhoven - 2017.08.28 16:02
    This manufacturers not only respected our choice and requirements, but also gave us a lot of good suggestions, ultimately, we successfully completed the procurement tasks.
    5 Stars By Honorio from California - 2018.09.29 13:24
    Write your message here and send it to us