Have a question? Give us a call: +8613911515082

China OEM Through Coating Ultrasonic Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our great management, potent technical capability and strict excellent handle procedure, we continue on to provide our customers with reputable top quality, reasonable selling prices and great providers. We purpose at becoming amongst your most trusted partners and earning your satisfaction for Test Block, Mini Digital Thickness Gauge, Ultrasonic Transducer Array, All products come with good quality and perfect after-sales services. Market-oriented and customer-oriented are what we have been being after. Sincerely look forward to Win-Win cooperation !
China OEM Through Coating Ultrasonic Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck Detail:

● 2 Measuring modes: continuous/single
● 2 Shutdown modes: manual/automatic
●Wide measuring range with 5 probes available (next page)
●Direct testing mode and block statistics mode (APPL/BATCH)
●Can connect with printer to out of statistical values
●Dataview to connect with PC with USB 2.0 port
●500 datas can be stored

Main features
Can use various probe (F400, F1, F1/90 °, F10, N1, N400, etc.) measurement;
Three calibration methods: one point calibration, two point calibration, the basic calibration;
Display resolution: 0.1 um (measuring range of less than 100 um)
1μ m (range greater than 100 u m)
Have five statistics, data storage 500
There are two working methods: direct ways and means of group
There are two measurements: continuous measurement and a single measurement
There are two shutdown: manual and automatic shutdown shutdown
Can be set Bound: The gauge of the measured value can be automatic alarm and a number of measurements available on the histogram value analysis;
Deleted features: the gross error and error settings can be deleted;
Printing: Print Measurement measurement, statistics, gauges, histogram
A music tone in the operation carried out at any time tips
A power supply under-voltage direct function
An error function
And printers, computer communications (communications software operating environment for the Window operating system) connectivity.

Technical Specifications:

Measuring range 0-1250µ with standard probe F1.N1 (10.000mm    max)
Probes available 5 probes available for F (ferrous: on steel/iron) and N (non-ferrous metals)
Tolerance F1:±(1µ+3%H) N1.±(1.5µ+3% H)H: actual thickness tested
Resolution Alphanumeric with 4 large digits
Operation language English
Standards DIN, ISO, ASTM,BS
Min. measuring area F1:(standard probe)
Min. curvature  radius convex:3mm, concave:50mm
Min. substratethickness type F: 0.5mm, type N: 50mm
Calibration Zero and foil calibration
Statistics Number of measurements, mean, standard deviation,maximum and minimum of 3000readings
Data memory 500  measuring data
Limits Adjustable with acoustic alarm
Interface USB 2.0
Operating temperature 0-40℃
power supply AA size 1.5V
Dimensions 125*67*31mm (main unit)
Weight 345.g

Standard Delivery

·  Main unit 1
·  Probe F1 or N1 1
·  Calibration foils 5
·  Instruction manual 1
·   Cetificate 1
·  Warranty card 1
·  Carrying case 1
Communication cable 1
PC software Dataview 1

Optional accessories
●5 probes for different applications
●Calibration foils in various thickness

Type F probe:

Probe

F400

F1

F1/90°

F10

Measuring Principle

Magnetic method

Measuring range(mm)

0~400um

0~1250 um

0~10000

Min resolution(mm)

0.1

0.1

10

Tolerance

One-point calibration (mm)

±(2%H+0.7)

±(2%H+1)

±(2%H+10)

Two-point calibration (mm)

±(1%H+0.7)

±((1%H+1)

±(1%H+10)

Minimum radius of curvature (convex) (mm)

1

1.5

flat

10

 Minimum measuring area(mm)

F3

F7

F7

F40

Minimum thickness of base material(mm)

0.2

0.5

0.5

2

Type N probe

Probe N400

N1

CN02

Measuring Principle

Eddy current method

 Measuring range (mm)

0~400

0~1250

10~200

 Min resolution(mm)

0.1

0.1

1

Tolerance  One-point calibration (mm)

±(2%H+0.7)

±(2%H+1.5)

±(2%H+1)

 Two-point calibration (mm) ±(1%H+0.7) ±(1%H+1.5)

——–

Minimum radius of curvature (convex) (mm)

1.5

3

flat

Minimum measuring area(mm)

F4

F5

F7

Minimum thickness of base material(mm)

0.3

0.3

0

 


Product detail pictures:


Related Product Guide:

Which has a positive and progressive attitude to customer's desire, our corporation constantly improves our merchandise quality to satisfy the desires of consumers and further focuses on safety, reliability, environmental demands, and innovation of China OEM Through Coating Ultrasonic Thickness Gauge - TM510FNplus Coating thickness gauge – TMTeck , The product will supply to all over the world, such as: Georgia, Chile, America, Our products and solutions are sold to the Middle East, Southeast Asia, Africa, Europe, America and other regions, and are favorably appraised by clients. To benefit from our strong OEM/ODM capabilities and considerate services, be sure to contact us today. We will sincerely create and share success with all clients.
Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
5 Stars By Rosemary from Tajikistan - 2017.11.01 17:04
The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
5 Stars By Victoria from Bulgaria - 2017.05.02 11:33
Write your message here and send it to us